Regency P42-NG4 No Vent restrictor is required, Vent must be supported at offsets, Diagram

Models: P42-LP4 P42-NG4

1 48
Download 48 pages 16.72 Kb
Page 18
Image 18
•No Vent restrictor is required.

INSTALLATION

The P42 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft (3.7m) horizontal offset using two 90o elbows (two 45o elbows equal one 90o elbow) with rigid pipe vent systems for Propane and Natural Gas, as per the diagram below.

No Vent restrictor is required.

Vent must be supported at offsets

The P42 is approved for a 37 ft. (11.3m) straight vertical,withrigidpipeventsystemsforPropane and Natural Gas, as per the diagram below.

Vent restrictor #6 must be used

Diagram 3

Note: Regency® Direct Vent System (Flex) is only approved for horizontal terminations.

Diagram 4

18

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

Page 18
Image 18
Regency P42-NG4 No Vent restrictor is required, Vent must be supported at offsets, Vent restrictor #6 must be used