Regency P42-NG4 Shutdown Procedure, First Fire, Normal Operating Sounds Of Gas Appliances, Blower

Models: P42-LP4 P42-NG4

1 48
Download 48 pages 16.72 Kb
Page 36
Image 36
appliance is lit, it may cause

MAINTENANCE

1)Push in gas control knob slightly and turn Note: When the glass is cold and the

clockwise to "OFF". Knob cannot be turned

appliance is lit, it may cause

from"PILOT"to"OFF"unlessknobispushed

condensation and fog the glass.

This condensation is normal and will

in slightly. Do not force.

disappear in a few minutes as the

 

2) Wait 5 minutes to clear out any gas.

glass heats up.

 

Unit Body/Firebox:

Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

3)Turn knob on gas control countercloskwise to "PILOT".

4)Push in control knob all the way and hold in. Immediately push black button on spark igniter until pilot lights. Continue to hold the control knob in for about 1/2 minute after the pilot light is lit. Release knob and it will pop back up. Pilot should remain lit.

5)Turn gas control knob counterclockwise to "ON".

6)Use rocker switch to operate main burner.

SHUTDOWN

PROCEDURE

1)Use the wall switch, thermostat or remote control to turn off the main burner.

2)Turn the main gas control clockwise to the "OFF" position to turn off the pilot.

3)Turn off all electric power to appliance if service is to be performed.

FIRST FIRE

The fi rst fi re in your fi replace is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the

rst time you use it with the fan on. When fi rst operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the

unit has cooled down.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot.

NORMAL OPERATING

SOUNDS OF

GAS APPLIANCES

It is possible that you will hear some sounds from your gas appliance.This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples.All are normal operatingsoundsandshouldnotbeconsidered as defects in your appliance.

Blower:

Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.

Burner Tray:

The burner tray is positioned directly under the burner tube and logs and is made of a different gauge material from the rest of the fi rebox and body.Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.

Blower Thermodisc:

When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal.

Pilot Flame:

While the pilot fl ame is on it can make a very slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.

MAINTENANCE

INSTRUCTIONS

1)Alwaysturnoffthegasvalvebeforecleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.

2)Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fi replace glass cleaner.

The glass should be cleaned when it starts looking cloudy.

3)The heater is fi nished in a heat resistant paint and should only be refinished with heat resistant paint. Regency® uses StoveBright Paint - Metallic Black #6309.

4)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call an authorized service person.

5)The appliance and venting system must be inspected before use, and at least annually, by an authorized fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.

6)Verify proper operation after servicing.

Note: Neveroperatetheappliancewithout the glass properly secured in place.

36

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

Page 36
Image 36
Regency P42-NG4 Shutdown Procedure, First Fire, Normal Operating Sounds Of Gas Appliances, Maintenance Instructions