Regency P42-LP4, P42-NG4 4” x 6-5/8”Rigid Pipe Cross Reference Chart Cont, Offset Pipe Selection

Models: P42-LP4 P42-NG4

1 48
Download 48 pages 16.72 Kb
Page 13
Image 13
4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.)

INSTALLATION

4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.)

Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

Description

Simpson

Simpson

Selkirk

American Metal

Metal-Fab®

Security

Direct Vent GS®

Products

®

Direct Vent Pro®

Discontinued

Direct-Temp™

 

Sure Seal

Secure Vent®

 

 

 

Amerivent Direct

 

 

Attic Insulation Shield 12”

46DVA-IS - N/A from FPI

N/A

N/A

4DAIS12

 

N/A

SV4RSA

Attic Insulation Shield - Cold Climates 36”

N/A

N/A

N/A

4DAIS36

 

N/A

N/A

Basic Horizontal Termination Kit (A)

Horizontal Termination Kit (B)

Vertical Termination Kit

DISC. 46DVA-KHA (Changed Components) DISC.

970

971

978

4DT-HKA

4DT-HKB

4DT-VKC

4DHTK2

4DHTK1

4DVTK

4DHTKA

4DHTKB

4DVTK

SV - SHK

SV - HK

SV - FK

High Wind Vertical Cap

High Wind Horizontal Cap

Horizontal Square Termination Cap

Vertical Termination Cap

Storm Collar

46DVA-VCH

46DVA-HC

Disc - See 46DVA-HC 46DVA-VC 46DVA-SC

991

985

984

980

953

N/A

N/A 4DT-HHC 4DT-HVC 4DT-SC

N/A

N/A

4DHC

4DVC

4DSC

N/A

N/A

4DHT

4DVT

4DSC

N/A

N/A SV4CHC-1 SV4CGV-1 SV4FC

Adjustable Flashing, 0/12-6/12 Adjustable Flashing, 6/12-12/12

46DVA-F6 46DVA-F12

943

943S

4DT-AF6 4DT-AF12

4DF

4DF12

4DF 4DF-12

SV4FA

SV4FB

Vinyl Siding Standoff Vinyl Siding Shield Plate

46DVA-VSS N/A

950

N/A

4DT-VS 4DT-VSP

N/A

N/A

4DVS

N/A

SV4VS

SV4VS

Snorkel Termination 14” Snorkel Termination 36”

46DVA-SNK14 N/A

982

981

4DT-ST14 4DT-ST36

4D12S

4D36S

4DST14

4DST36

SV4STC14

SV4STC36

Restrictor Disk

Extended Vertical Termination Cap

Chimney Conversion Kit A

Chimney Conversion Kit B

Chimney Conversion Kit C

Chimney Conversion Kit Masonry

Mansonry Chimney Conversion Kit

(includes: Cap Adapter 18”x18” Flashing)

Wall Firestop

Colinear Flex Connectors

46DVA-RD 46DVA-VCE 46DVA-KCA 46DVA-KCB 46DVA-KCC 46DVA-KMC

46DVA-KCT

46DVA-WFS 46DVA-ADF

929

930

931

932

933

934

935

947

923F

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

FPI

946-506/P

Vent Guard (Optional) for AstropCap

946-205

Vinyl Siding Shield for Riser Vent Terminal

510-994

Rigid Pipe Adapter (Must use with all Rigid Piping)

946-208/P

Vent Guard (Optional) for Riser Vent Terminal

640-530/P

Riser Vent Terminal

946-523/P

AstroCap Horizontal Cap

 

 

946-206

Vinyl Siding Standoff for AstroCap

 

 

 

 

*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (4DDA) or 90º Starter Elbow (4D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Offset Pipe Selection:

Use this table to determine offset pipe lengths.

Pipe Length

4” x 6-5/8” Venting

 

 

Run (X)

Rise (Y)

 

 

 

 

0”(0mm)

4-7/8”(124mm)

13-3/8”(340mm)

 

 

 

6”(152mm)

8”(203mm)

16-1/2”(419mm)

 

 

 

9”(229mm)

10-1/8”(257mm)

18-5/8”(473mm)

 

 

 

12”(305mm)

12-1/4”(311mm)

20-3/4”(527mm)

 

 

 

24”(610mm)

20-5/8”(524mm)

29-1/8”(740mm)

 

 

 

36”(914mm)

29”(737mm)

37-1/2”(953mm)

 

 

 

48”(1219mm)

37-7/16”(951mm)

45-15/16”(1167mm)

 

 

 

L

X

Y

For specific instructions or details on particular venting components please visit the following websites:

Simpson Direct Vent Pro: www.duravent.com

Selkirk Direct-Temp: www.selkirkcorp.com

American Metal Products Amerivent Direct: www.americanmetalproducts.com

Metal-Fab Sure Seal: www.mtlfab.com

Security Secure Vent: www.securitychimneys.com

NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present a possible fire hazard.

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

13

Page 13
Image 13