Regency P42-LP4 Gold-Platedglass Louvers Replacement, Log Replacement, Thermopile Thermocouple

Models: P42-LP4 P42-NG4

1 48
Download 48 pages 16.72 Kb
Page 37
Image 37
GOLD-PLATEDGLASS

MAINTENANCE

GOLD-PLATEDGLASS

LOUVERS REPLACEMENT

Caution: Wear gloves when removing damaged or broken glass.

The 24 carat gold-plated fi nish on the louvers and trim requires little maintenance, and need only be cleaned with a damp cloth.

DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.

Clean any fingerprints off before turning the unit on.

Your P42 fireplace is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break the glass, purchase your replacement glass from an authorized Regency® dealer only, and follow the step-by-step instructions for glass, glass gasket and door gasket replacement.

Bay Glass Replacement

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Remove the nuts holding the glass clips in place and remove.

3)Replace the glass. The glass must have gasketing around it.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will severely alter the unit's performance which is not covered under warranty.

THERMOPILE /

THERMOCOUPLE

1)Remove the top louver and open the bottom louvers.

2)Open and remove door.

3)Remove front logs.

4)Remove burner.

5)Loosen the thermocouple or thermopile with a 7/16" wrench.

6)Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Disconnect thermopile by loosening 2 screws marked TP on the valve.

7)Peel the silicone from the hole in the base of the unit and drop the thermocouple or thermopile down from the bracket and pull it out of the unit.

8)Reinstall the new ones in reverse order making sure to seal the hole in the fi rebox with silicone in order to maintain the seal integrity of the fi rebox.

DOOR GLASS

Your Regency® fi replace is supplied with high temperature,5mmNeoceramceramicglassthat will withstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only, and follow our step-by- step instructions for replacement.

WARNING

The use of substitute glass will

void all product warranties.

Do not operate the appliance

with the glass panel(s) removed, cracked or broken. Replacement of the glass panel(s) should be done by an authorized service person.

Flush Glass Replacement

Removetheflushdoorfront(asperinstructionsin the "Standard Flush Door" section). Remove the 4 glass clips from each corner. Slide in the new replacement

glass. Push the 4 glass clips back onto the frame.

Theglassmust havegasketing around it.

4)Reverse the previous steps, replace the glass clips and fasten with the nuts but do not over tighten, as this can break the glass.

5)Replace door on the fi replace and check the seal.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

37

Page 37
Image 37
Regency P42-LP4, P42-NG4 Gold-Platedglass Louvers Replacement, Log Replacement, Thermopile Thermocouple, Door Glass