INSTALLATION
VERTICAL TERMINATION
WITH
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76mm)
Required Parts:
Part # | Description |
| Termination Cap |
3" Flex - 35 ft. | |
| which contains the following: |
| |
| Outer Pipe |
| Inner Pipe Adapter |
Rigid Pipe Adaptor |
Alternate Approved Caps
980Vertical Termination Cap
991High Wind Cap
923GK 3"
FPI Cabinet and/or Flat Wall Mantles may be used in these applications ensuring that clearances to combustibles are maintained.
Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Vertical Termination
Cap #
Amaximum of two certified
joiner kits |
|
may be used |
|
per length. | Flex Liner |
|
Exhaust
Flue
Outer |
|
| |
Pipe |
|
| |
with Kit# |
|
| |
|
| ||
|
| Air Intake | |
Pipe Length |
| ||
|
| ||
|
| Flex | |
|
| Adapter | |
Rigid Pipe Adapter |
| with Kit# | |
| |||
# | 90 Degree | ||
| |||
| Elbow | Inner Pipe | |
|
| ||
|
| Adapter | |
|
| with Kit# | |
|
|
Regency® | 19 |