Regency P42-LP4, P42-NG4 Vertical Termination With Co-Linearflex System, Required Parts

Models: P42-LP4 P42-NG4

1 48
Download 48 pages 16.72 Kb
Page 19
Image 19
VERTICAL TERMINATION

INSTALLATION

VERTICAL TERMINATION

WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements on next page for minimum and maximum heights.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical

 

Termination Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter Kit

 

which contains the following:

 

Co-linear Flex Adapter

 

Outer Pipe

 

Inner Pipe Adapter

510-994

Rigid Pipe Adaptor

Alternate Approved Caps

980Vertical Termination Cap

991High Wind Cap

923GK 3" Co-linear Adapter with fl ashing

FPI Cabinet and/or Flat Wall Mantles may be used in these applications ensuring that clearances to combustibles are maintained.

Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Co-linear DV

Vertical Termination

Cap # 946-529

Amaximum of two certified

joiner kits

 

may be used

 

per length.

Flex Liner

#948-305 (35 ft)

 

Exhaust

Flue

Outer

 

 

Pipe

 

 

with Kit#

 

 

946-563

 

 

 

 

Air Intake

Pipe Length

 

Co-Linear

 

 

 

 

Flex

 

 

Adapter

Rigid Pipe Adapter

 

with Kit#

 

946-563

# 510-994

90 Degree

 

 

Elbow

Inner Pipe

 

 

 

 

Adapter

 

 

with Kit#

 

 

946-563

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

19

Page 19
Image 19
Regency P42-LP4, P42-NG4 installation manual Vertical Termination With Co-Linearflex System, Required Parts