INSTALLATION
System Data
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes:
Natural Gas Propane
| Burner | #33 |
| #50 |
|
|
|
|
|
| |
| Max. Input Rating |
|
|
| |
| - Natural Gas |
| 35,000 | Btu/h | |
| - Propane |
| 35,000 | Btu/h | |
| Min. Input Rating |
|
|
| |
|
| 17500 | Btu/h | ||
|
| 17500 | Btu/h | ||
|
|
| |||
| Output Capacity with blower Off | ||||
| Natural Gas |
| 25,725 | Btu/h | |
| Propane |
| 26,740 | Btu/h | |
| Output Capacity with blower On | ||||
| Natural Gas |
| 26,250 | Btu/h | |
| Propane |
| 27,300 | Btu/h | |
|
|
|
|
| |
| Supply Pressure |
|
|
| |
| Natural Gas | min. | 5.0" w.c. | ||
| Propane | min. | 11.0" w.c. | ||
|
|
|
| ||
| Manifold Pressure (High) |
|
| ||
| Natural Gas | 3.8" | +/- 0.2" w.c. | ||
| Propane | 10" | +/- 0.2" w.c. |
Electrical: 120 V A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fi bre, 3 per set.
Vent System: Simpson
Note: Output capacity. The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system. Vent height may or may not change your efficiency ratings.
HIGH ELEVATION
This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1
GAS LINE
INSTALLATION
The gas line can be brought through either the right or the left side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve.
Note: If the gas line is being installed from the left side, be sure to leave room to accommodate servicing of the fan.
The gas line connection may be made of rigid pipe, copper pipe or an approved flex connector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.
For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.
When using copper or fl ex connectors use only approved fittings.Always provide a union so that gas lines can be easily disconnected for burner or fan servicing. Flare nuts for copper lines and
flex connectors are usually considered to meet this requirement.
Important:Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual
Themanifoldpressureiscontrolledbyaregulator built into the gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1)Make sure the valve is in the "OFF" position.
2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" (3mm) wide fl at screwdriver.
3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" (8mm) ID hose.
4)Light the pilot and turn the valve to "ON" position.
5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.
6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8"(3mm) fl at screwdriver. Note: Screw should be snug, but do not over tighten.
S.I.T. Valve Description
1)Gas on/off knob
2)Manual high/low adjustment
3)Pilot Adjustment
4)Thermocouple Connection - option
5)Outlet Pressure Tap
6)Inlet Pressure Tap
7)Pilot Outlet
8)Main Gas Outlet
9)Alternative TC Connection Point