A vent guard may be required, check local codes.

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

REGENCY® DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas)

The shaded areas in the diagram show all allowable combinations of vertical runs with horizontal terminations. The chart below shows the distances with one 90o bend (two 45o elbows equal one 90o elbow). For a second 90o bend, see the "Rigid Pipe Venting Arrangements - Horizontal Terminations" section.

 

A vent guard may be required, check local codes.

Minimum height

Note: Must use optional rigid pipe adaptor (Part # 510-994)

when using rigid pipe venting systems.

requirement

 

 

Rigid Pipe Systems:

 

4"(100mm) inner diameter

 

6-5/8"(168mm) outer diameter

 

Regency® Flex:

 

4"(100mm) inner diameter

 

6-7/8"(175mm) outer diameter

Rigid Pipe Systems: Maintain a 1-1/4"(32mm) clearance to combustibles

Regency® Flex: Maintain a 1-1/2"(38mm) clearance to combustibles

Horizontal vent must be supported every 3 feet (0.9 meter)

Firestops are required at each floor level and whenever passing through a wall

Note: Regency® Direct Vent System (Flex) is only approved for horizontal terminations.