Regency P42-NG4 For All Horizontal Terminations, Horizontal vent must be supported every 3 feet

Models: P42-LP4 P42-NG4

1 48
Download 48 pages 16.72 Kb
Page 16
Image 16
For All Horizontal Terminations

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

REGENCY® DIRECT VENT SYSTEM (FLEX) - Propane & Natural Gas

The diagram below shows examples of horizontal termination arrangements using two 90o elbows.

Note:

1)

A maximum of two 90o elbows are permitted (two 45o elbows equal one 90o elbow).

 

2)

A minimum of 6 ft.(1.8m) vertical from base of unit is required if two 90o elbows are used.

 

3)

Minimum distance between elbows is 2 ft. (0.6m).

If length "B" is increased, length "A" must be decreased by a corresponding amount.

For All Horizontal Terminations

All Rigid Pipe Systems 4" inner diameter

6-5/8" outer diameter

Regency® Flex Vent 4" inner diameter

6-7/8" outer diameter

A vent guard may be required, check local codes.

Maintain a 1-1/4" clearance to combustibles for rigid pipe systems and 1-1/2" for Regency® Flex Vent.

Horizontal vent must be supported

every 3 feet

Firestops are required at each floor level and whenever passing through

a wall.

Note: Regency®DirectVentSystem(Flex)isonly approved for horizontal terminations.

16

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

Page 16
Image 16
Regency P42-NG4, P42-LP4 For All Horizontal Terminations, Horizontal vent must be supported every 3 feet, a wall