Regency P42-LP4 Vent must be supported at offsets, Note Must use optional rigid pipe adaptor

Models: P42-LP4 P42-NG4

1 48
Download 48 pages 16.72 Kb
Page 17
Image 17
•Vent must be supported at offsets

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS

(Propane & Natural Gas)

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas.

Maximum two 45o elbows allowed.

Vent restrictor #6 must be used in shaded area in diagram below.

Vent must be supported at offsets

The P42 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset using two 90o elbow (two 45o elbows equal one 90o elbow) with rigid pipe vent systems for Propane and Natural Gas, as per the diagram to the right.

Vent restrictor #6 is required for terminations in shaded area.

Vent must be supported at offsets.

Note: Must use optional rigid pipe adaptor

 

when using rigid vent systems (Part

 

# 510-994).

 

Note: Regency® Direct Vent System (Flex)

 

is only approved for horizontal

 

terminations.

 

Diagram 1

Diagram 2

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace

17

Page 17
Image 17
Regency P42-LP4, P42-NG4 Vent must be supported at offsets, Note Must use optional rigid pipe adaptor, terminations