Changing Batteries

WARNING: To reduce the risk of injury from unexpected starting, unplug the saw whenever you are removing or installing the blade.

1.Remove the Exactline™ Laser System from the saw.

2.Remove the two Phillips screws on the back side of the laser system and take off the back cover.

3.Remove the three batteries with a non- conductive device (toothpick).

4.Use a soft paintbrush to gently and carefully clean all sawdust from the laser system.

5.Insert the new batteries. Replacement batteries must have a rating of 1.5 volt and 100 mah (milliampere hour) mini- mum. Number 76 series or equivalent.

DANGER:

Laser radiation when open and interlock defeated.

Do not attempt to activate the laser.

Avoid direct eye contact.

The laser is activated by means of a centrifugal switch only while the saw motor is running and the laser system is mounted on the saw.

6.Replace the back cover and secure with two Phillips screws.

Screws

Laser Guide

Aperature

Cover

Key

 

Key Slot

Batteries

Laser Guide

Negative (-)

Support

 

Aperature

41

Page 41
Image 41
RIDGID MS1290LZ manual Changing Batteries, Replace the back cover and secure with two Phillips screws