Step 7.2 U-Tube Hanger Placement

SECTION 7: U-TUBE HEATER INSTALLATION

Step 7.2 U-Tube Hanger Placement

 

Spreader

Bow

Bar

Shackle

Threaded

 

Suspension

Bar

 

Chain

 

Washers

Bolt

(Torque:

13.5Nm 129 in lb)

Step 7.3 Burner Tube and Fan Tube Installation Tube and Reflector

Hanger

Optional

Hanging

Configuration

First Tube and Offset mounting hole must be to the top.

Reflector Hanger

2290 mm ± 250 mm Weld seam must be to the bottom of the tube

Description

Part Number

Bow Shackle

E0007576

Tube/Reflector Hanger

03090100

Spreader Bar

07260010

NOTE: Spreader bar must be used on single suspension point installations. Do not hang heater from spreader bar.

Bow

Shackle

Suspension

Chain

Tube and Reflector

Hanger

See Assembly

Drawing

Step 7.3 Burner Tube and Fan Tube Installation

Offset mounting hole must be to the top.

Weld

Spot

Fan Tube

Burner Tube29 of 75

Weld seam must be to the bottom of the tube

Description

Burner Tube

Fan Tube

Part Number

03051100

S5127W