Roberts Gorden BH60DL/EF Operation, Burn Hazard, Disconnect electric, Turn off gas supply to

Models: BH45ST/EF BH20UT BH50ST/EF BH55ST BH70DL/EF BH45UT/EF BH50UT/EF BH40UT/EF BH30DL BH15UT BH25ST/EF BH30ST/EF BH50DL/EF BH40ST/EF BH15ST BH20ST BH25UT/EF BH60DL/EF BH35ST/EF BH40DL BH30UT/EF BH35UT/EF

1 84
Download 84 pages 15.61 Kb
Page 64
Image 64
SECTION 14: OPERATION

BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL

SECTION 14: OPERATION

DANGER

 

WARNING

 

Electrical Shock Hazard

Explosion Hazard

Burn Hazard

Cut/Pinch Hazard

Disconnect electric

Turn off gas supply to

Allow heater to cool

Wear protective gear

heater before service.

before service.

during installation,

before service.

 

 

operation and service.

 

 

Tubing may still be hot

More than one

 

Edges are sharp.

disconnect switch may

 

after operation.

be required to

 

 

 

disconnect electric from

 

 

 

heater.

 

 

 

Heater must be

 

 

 

connected to a properly

 

 

 

grounded electrical

 

 

 

source.

 

 

 

Failure to follow these instructions can result in death, electric shock, injury or property damage.

Figure 35: Sequence of Operation Chart

KEY TO

SYMBOLS

Thermostat

Fan

Pressure

P Switch

Neon

Ignition

Gas

Valve

Flame

Sensing

Lockout Alarm

Signal (optional)

T0

T1

T2

T3

T4

T5

T6

T7

T8

P

 

 

 

 

 

 

 

 

Fan Neon

 

 

 

 

 

 

 

 

Burner Neon

 

 

 

 

 

 

 

 

 

 

Tp

 

 

Tp

 

Ts

 

 

10 sec

 

 

10 sec

 

10 sec

 

 

40 sec max.

 

 

Interruption of main

 

Burner Lockout

11 sec typical

 

 

flame sensing

 

signal received after

 

 

 

 

 

 

 

3 ignition trial

 

 

 

 

 

 

 

 

failures

NOTE: If the heater operates for more than 24 hours continuously, the ignition module will automatically recycle the burner to ensure that all safety functions are still in working condition.

14.1 Heater Lockout Indication (Optional)

In case of flame loss during operation of the heater, the burner control unit goes to lockout mode after three ignition trials. At this stage a signal or closed relay will enable the ROBERTS GORDON® controller, BMS

58 of 74

system, etc. to indicate precisely which heater has failed. This can be done by two options.

Page 64
Image 64
Roberts Gorden BH60DL/EF Operation, Burn Hazard, Disconnect electric, Turn off gas supply to, Allow heater to cool, source