CORRECT POSITIONS

BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL

Figure 34: Gas Connection with Stainless Steel Flex Connector

CORRECT POSITIONS

Stainless Steel Flexible Connector

 

Shut-Off Valve

supplied by Roberts-Gordon 1000 mm Long

 

 

Minimum Bend Radius 140 mm

 

45°

45°

 

 

Gas Supply Pipe

 

 

Flex Line

 

 

 

Connector 545 mm

 

 

 

minimum

 

 

Burner

 

 

Correct position with flex connector not supplied by Roberts-Gordon.

Shut-Off Valve

 

(included with gas

 

hose) must be parallel

 

to burner gas inlet. The

 

80 mm displacement

 

shown is for the cold

80 mm

condition. This

max. displacement

displacement may

300 mm

reduce when the

Side View

system is fired.

 

 

Heater Movement

Flexible Gas Hose

1000 mm length

Manual backgroundCAUTION

Product Damage Hazard

Hold gas nipple securely with pipe wrench when attaching gas hose.

Failure to follow these instructions can result in product damage.

INCORRECT POSITIONS (WRONG INSTALLATION)

Heater Movement

 

 

 

 

 

Heater Movement

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater Movement

Heater Movement

 

 

 

 

 

 