BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL

the attention of the user or purchaser; instruct them in the safe operation of the heater(s). Advise the user that if the system is unflued, any reduction in the natural ventilation of the building may require a flue to be fitted, or additional ventilation grilles will be required.

14.6 ECA Approved Systems (Multiburner only)

On ECA approved systems, it must be verified that the requirement of 91% net combustion efficiency is met. Measurements of temperature and CO2 concentration in the exhaust gasses have to be done. The net combustion efficiency calculates as follows;

100 - [ (tE - tR) (A/CO2m - B) ] = net combustion efficiency

tE

- Exhaust Temperature °C

tR

- Room Temperature °C

A- G20 = 0.37, G31 = 0.42

B - G20 = 0.009, G31 = 0.008

CO2m - Measured CO2 Concentration %

60 of 74

Page 66
Image 66
Roberts Gorden BH15ST BH20ST, BH35UT/EF, BH30UT/EF, BH40DL, BH35ST/EF, BH60DL/EF, BH15UT ECA Approved Systems Multiburner only