71
Chapter 2 Making the Pad and Trigger Settings (SETUP/TRIG)
2
4.
Disconnect the connecting cable, then connect
two pads to TRIGGER INPUT 5/6 and 7/8 using
the optional cable (PCS-31).
When connecting the pads, refer to the instructions in
“Connecting Two Pads to Trigger Inputs 5/6 (TOM2/
AUX) and 7/8 (TOM3/4)” (p. 21).
5.
Press [+] and [-] to set the trigger type for the
pads used for AUX and TOM4.
To enable the TOM2 and TOM3 rims again, set the AUX
and TOM4 trigger type to "Rim."
If you hit a rim shot BEFORE restoring the AUX and
TOM4 trigger type to "Rim" while a PD-8 or other pad is
connected, the AUX and TOM4 sounds will play instead
of the TOM2 and TOM3 rim sounds, and the dynamic
response won't be correct. Change the settings back to
"Rim."
You can assign different instruments to TOM2 and AUX,
and TOM3 and TOM4.
Setting the Pad Sensitivity and Making Other Settings (TRIGGER BASIC)
You can make more detailed settings for the pad type and
sensitivity.
The following parameters (Basic Trigger Parameters except
the “Xtalk Cancel”) are automatically set to the most efficient
values for each pad when you select the “TrigTyp (Trigger
Type)” (SETUP/TRIG BASIC/TrigTyp; p. 69).
Make the settings for each parameter as needed.
1.
While holding down [SHIFT], press [EDIT
(SETUP)].
[EDIT] lights.
2.
Press [ ] to select “TRIG BASIC.”
fig.SETUP-BASIC_50
3.
Press [ENTER ].
4.
Press [ ] or [ ] to select the parameter you
wish to edit.
fig.02-004ai.e
5.
Strike the pad you wish to set.
The settings screen for the struck pad appears, and the
input indicator fluctuates.
6.
Press [+] or [-] to make the setting.
fig.02-005ai.e
7.
When you finish making settings, press [KIT] or
[SONG] to end the procedure.

Adjusting the Pad Sensitivity (Sensitivity)

Adjust the sensitivity of the pad to regulate the pad response.
Higher settings result in higher sensitivity, so that the pad will
produce a loud volume even when struck softly.
Adjust the “Sensitivity” value so that the strongest strikes
cause the input indicator (p. 69) to reach nearly all the way to
the maximum level.
Parameter to set
Value
TD-6KV_e.book 71ページ 2005年1月24日 月曜日 午後7時4分