182
Chapter 7 Loading a Variety of Data
1. Turn off the power on the XV-5080 and any connected
devices, and disconnect any cables connected to the XV-
5080.
2. Detach the cover on the top of the XV-5080.
fig.07-002.e
3. The order in which the slots are used when installing the
SIMMs depends on the number of SIMMs added. Refer
to the table below.
SIMM Slot Installation Order
Two cards: A, then B
One card: A
4. After confirming the position of the SIMMs notch and its
orientation, insert the SIMM at an angle into the slot.
5. Using your fingers, push up on the SIMM until it stands
upright in the slot.
The SIMM is then held in place with the silver-colored
latches on both sides of the slot.
fig.07-003.e
6. When installing more than one SIMM, repeat Steps 4 and
5.
7. Return the XV-5080s top cover to its original position.
This completes installation of the SIMM or SIMMs.
Removing SIMMs
Remove SIMMs in the reverse order of that used for
installation.
Before beginning this procedure, turn off the power to the
XV-5080 and all connected devices.
1. Simultaneously push the silver-colored latches on both
sides of the slot outwards.
The SIMM is released from the latches, and remains in the
slot, at an angle.
fig.07-004.e
2. Pull the SIMM out of the slot.

Confirming That the SIMM Is Properly

Installed

1. Press the [SYSTEM/UTILITY] button, getting its
indicator to light.
* If the indicator is blinking, you are in UTILITY mode. Press
the [SYSTEM/UTILITY] button again, so the indicator lights
steadily.
2. Press the [F6 (Info)] button.
The SYSTEM Info page will appear.
3. Confirm that the capacity of the SIMM appears next to
the slot in which it is placed.
* If no SIMM has been installed, or if the installed SIMM is not
being recognized properly, “—–” appears in the display.
* If the SIMM is not properly recognized, or if the capacity
indicated for the installed SIMM differs from its actual
capacity, turn off the power, and carry out the procedure once
more. Check again, and if you get the same result, it means
that that particular SIMM cannot be used in the XV-5080.
A
B
Screws to be removed
A
A