INSTALLER

MAKING CONNECTIONS

A-BUS Ready Sub-zone Connection

A-BUS products can easily expand the CAV6.6 audio system by adding A-BUS Ready Sub-zones to the first four CAV6.6 zones. The A-BUS Ready Sub-zones are located on the back of the CAV6.6 at the bottom left corner. The A-BUS Ready Sub-zones are powered by a 24VDC power supply such as the A-PS.

Use an RJ-45 CAT-5 T568A configuration patch cable to connect the A-BUS Ready Sub-zone

port to an RJ-45 wall plate (optional) for a clean installation. Using the same T568A RJ-45 wiring configuration, attach CAT-5 from the RJ-45 wall plate to an A-BUS hub or amplified control mod- ule such as the A-KP2 keypad.

If using an A-BUS hub with the A-BUS Ready Sub- zone, the hub should be located near the CAV6.6 and wired directly instead of first going through the wall plate.

34

Page 34
Image 34
Russound CAV6.6 Six-Zone instruction manual BUS Ready Sub-zone Connection