| English |
|
|
|
|
| |
- | Cup key | PAYMENT SYSTEMS | |||
It allows to enable or disable the key ‘beverage | The entries of the PAYMENT SYSTEMS are: | ||||
01’ (fig. 39) as: |
|
|
|
| |
|
| - | Parallel coiner | ||
1 - ‘No cup’: By pressing the | It allows you to enable the parameters of the | ||||
choosing a beverage allows to have it brewed | parallel coiner, of the mechanical coiner, the | ||||
without the cup. | cancelling machine and the choice of values to | ||||
After pushing the preselection key, the user has | assign to the single money channels. | ||||
8 seconds to select the desired product. After |
|
|
|
| |
this time the preselection is cancelled. | - | Enable |
|
| |
2 - ‘Beverage 05’: in this case, by pressing this | By setting ‘Y’, the control of the parallel coiner, | ||||
key the beverage 01 is brewed. | the mechanical coiner and the cancelling | ||||
3 - ‘Disabled’: in this case, by pressing this key | machine is enabled. | ||||
no beverage will be brewed. | By setting ‘N’, a parallel coiner possibly attached | ||||
|
| to the vending machine is disabled. | |||
- | Reset validation |
|
|
|
|
It allows to ‘RESET’ the data in the maintenance | - | Coin value | |||
menu (STATISTICS). | It allows setting the value of the coins transferred | ||||
|
| to the vending machine from the parallel coiner, | |||
- | Language | the mechanical coiner and the cancelling | |||
It allows to select the language to be used by | machine. |
|
| ||
the machine. | The following table shows the combinations | ||||
|
| channel/payment system. | |||
- | Modify password |
|
|
|
|
It allows to set a password or to modify the set |
|
|
|
| |
| Channel | Payment system | |||
one. The password consists of a number |
| ||||
between 0001 and 65536. The 0000 value |
|
|
|
| |
|
|
|
| ||
(default value) means no password. To set the |
| 1 | Parallel coiner | ||
password, press the UP and DOWN keys and |
| 2 | parallel coiner | ||
confirm using the ENTER key. |
| 3 | Parallel coiner | ||
- | Complete menu |
| 4 | Parallel coiner | |
| 5 | Parallel coiner | |||
It allows to choose whether the entries of the |
| 6 | Parallel coiner/mechanical | ||
programming menu should be shown entirely or |
|
| coiner | ||
only partially. The least frequently used entries |
| 7 | Canceling machine/mechanical | ||
are highlighted by a frame outlined at 8.2.2 and |
|
| coiner | ||
can be shown only if in the data ‘Y’ is set in this |
|
|
|
| |
|
|
|
| ||
function. | - | Banknote Reader | |||
|
| ||||
|
| It enables the parameters of the parallel banknote | |||
|
| validator and the choice of values to be assigned | |||
|
| to individual note channels. | |||
|
| - | Enable |
|
|
|
| By setting “Y”, management of the parallel reader | |||
|
| is enabled. |
|
| |
|
| By setting “N”, a parallel banknote reader | |||
|
| possibly connected to the vending machine is | |||
|
| disabled. |
|
| |
|
| - | Inhibition Level | ||
|
| It allows setting the active level of the banknote | |||
|
| reader’s inhibition level. |
37