English
10 - INACTIVITY
11 - DISMANTLING
If the automatic vending machine remains inactive for a long time it is necessary to take certain preventive measures:
-with the machine on, start the automatic emptying process of both the hydraulic circuit and the boiler (see PROGRAMMING AND MAINTENANCE MENU in section 8).
-once it is over, disconnect the machine from the power and hydraulic supply
-disassemble the closing panel on the back of the machine.
-complete the emptying of the tank with float by removing the hose clamp located on the
-once the emptying is over, refit the hose clamp (fig.64)
fig.64
-assemble the closing panel on the back of the machine.
-unload all products from the containers
-wash all the components that are in contact with foodstuff as previously described
-empty the trays from dry and liquid dumps, then clean them accurately
-clean all vending machine internal and external surfaces with a cloth
-protect the outside of the machine with plastic film or a bag
-store in dry, sheltered environments at a temperature not lower than 1°C
Empty the products and water as described in the previous section. For dismantling, it is advisable to disassemble the machine parts according to their composition - plastic, metal etc. Afterwards, deliver the divided parts to the specialised companies. If a refrigerating unit is present, give it without disassembling it to companies authorized for the disposal of this particular part.
55