Saeco Coffee Makers SG200E instruction manual English, position, mechanism did not end its

Models: SG200E

1 68
Download 68 pages 48.17 Kb
Page 58
Image 58
position

English

Description

 

 

Failure/

Error

Effect

on

the

 

Reset to normal operation

 

 

 

 

 

error

code - if

V M

 

 

 

 

 

 

 

 

 

 

 

category

any

 

 

 

Manual

Simplified

Self-reset

 

Reset by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reset

reset

 

 

start-up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES (the

VM

 

no water (see air-break

B/C

1

 

 

 

SI

SI*

makes

20

 

device control section)

 

 

stop VM

 

 

 

 

attempts,

one

SI

 

 

 

 

 

 

 

 

 

 

 

every

10

 

 

 

 

 

 

 

 

 

 

 

 

minutes, in case

 

 

 

 

 

 

 

 

 

 

 

 

of failure, it

 

 

 

 

 

 

 

 

 

 

 

 

displays error

 

 

 

 

 

 

 

 

 

 

 

 

01)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stop beverages

 

 

 

 

 

no coffee

 

 

A

2

with

coffee

SI

SI

NO

 

 

 

 

 

 

 

 

beans

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

brew group did not reach

A

3

stop beverages

YES

YES*

NO

 

 

the dispensing position

 

 

with

coffee

 

 

 

 

YES

 

 

 

 

 

 

beans

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

brew group did not reach

A

4

stop beverages

YES

YES*

NO

 

 

the rest position

 

 

 

 

with

coffee

 

 

 

 

YES

 

 

 

 

 

 

beans

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

turbine impulses not read

B

5

stop VM

 

 

YES

NO

NO

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cup bracket

not

in

A/B

6

b e v e r a g e s

YES

NO

NO

 

 

position

 

 

 

 

 

without

cup

/

 

 

 

 

YES

 

 

 

 

 

 

stop VM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

no cups

 

 

A/B

--- (8)

b e v e r a g e s

---

---

 

 

 

 

 

 

 

without

cup

/

 

 

YES

 

YES

 

 

 

 

 

 

stop VM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dump tray

 

 

B

--- (9)

stop VM

 

 

---

---

YES

 

YES

 

 

 

 

 

 

 

 

 

 

 

the

cup

release

A/C

10

b e v e r a g e s

 

 

 

 

 

mechanism did not end its

 

 

without

cup

/

YES

YES

NO

 

YES

movement

 

 

 

 

stop VM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wrong

value

of

the

 

 

 

 

 

 

 

 

 

 

temperature sensor

 

C

14

stop VM

 

 

YES

NO

NO

 

YES

 

 

 

 

 

 

 

 

 

 

 

corrupted data in eprom

 

 

 

 

 

 

 

 

 

 

data

 

 

 

C

16

stop VM

 

 

YES

NO

NO

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

20

stop beverages

 

 

 

 

 

no brew group

 

 

 

 

with

coffee

YES

YES*

YES

 

YES

 

 

 

 

 

 

beans

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

no dump box

 

 

B

--- (21)

stop VM

 

 

---

 

YES

 

YES

 

 

 

 

 

 

 

 

 

the last three coffees

 

 

stop beverages

 

 

 

 

 

had a scarce brewing

A

22

with coffee

 

YES

YES

NO

 

NO

flow

 

 

 

 

 

beans

 

 

 

 

 

 

 

 

 

 

 

 

 

failure

record

 

 

 

 

 

pump error

 

 

failure

23

only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

saeco card without clock

C

25

stop VM

 

 

 

 

 

 

 

(timekeeper)

 

 

 

 

YES

NO

NO

 

YES

 

 

 

 

 

 

 

 

 

 

 

payment system decimal

 

 

stop VM

 

 

YES

NO

---

 

YES

point not in line with the

C

31

 

 

 

VM settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(credit handler signal)

 

---

32

signal only

 

---

---

---

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

Page 58
Image 58