Air flow is detected around the door and outer casing.

This is a normal occurrence.

Light reflection around the door and outer casing.

This is a normal occurrence.

Steam escapes from around the door or vents.

This is a normal occurrence.

A clicking sound occurs while the oven is operating, especially in defrosting mode.

This is a normal occurrence.

Error and Safety codes

Error Code

General Functions

 

 

 

TEMP SENSOR OPEN

 

In case the value of the temperature sensor is more than 250 °C

 

during operation / cancellation.

 

 

 

TEMP SENSOR SHORT

 

In case the value of the temperature sensor is less than 5 °C

 

during operation / cancellation.

 

 

 

UNFINISHED PREHEAT

 

In case the oven has not reached the desired temperature

 

although a ceratin amount of time has passed (unfinished preheat)

 

 

 

OVER 230 °C DURING OPERATION OF MWO MODE

 

In case the temperature rises over 230 °C during operation of

 

mwo mode (fire sensed).

 

 

 

STEAM SENSOR OPEN

 

In case the value of the temperature sensor is less than 250 °C

 

after operation of the steam heater for a certain time.

 

 

 

STEAM SENSOR SHORT

 

In case the value of the temperature sensor is less than 5 °C after

 

operation of the steam heater for a certain time.

 

 

 

DESCALE MAX. TIME OVER (or STEAM USE MAX. TIME OVER)

 

In case the steam operation time after the descaling message has

 

been passed.

 

 

 

POWER ON EEPROM COMMUNICATION ERROR

 

 

 

EEPROM READ / WRITE ERROR

 

 

 

DO NOT SENSE DAMPER MOTOR FOR 1MIN

 

 