User’s Guide

To move “ ”, use the “MENU” button.

Use the “SELECT” button to set the “1. BUZZER” menu item.

If you choose “ON”, the alarm will warn whenever the alarm is on or channel loss is found. If you choose “OFF”, the alarm will not warn even though the alarm is on or channel loss is found. In the “2. ALARM RESET” menu, use the “SELECT” button to set the ALARM RESET TIME. This feature provides the alarm time that keeps the Alarm feature on while the alarm is on. Following are the alarm time intervals.

05 seconds

10 seconds 20 seconds 30 seconds 60 seconds

90 seconds

120 seconds 180 seconds Manual

NOTE

When M (manual) is selected, the alarm is armed only when the alarm signal input level is “LOW” in the TTL level.

When you finish setting the alarm mode, press “ENTER” button to return to the main menu.

If you want to continue with additional system setup, move “ ” to the desired menu item. When you have completed the setup mode, press the “SETUP” button to exit the system setup mode.

NOTE

What is TTL level?

TTL level “LOW” : 0V ~ 0.6V

TTL level “HIGH” : 5V