Samsung SCQ-041P, SCQ-041AP manual Disabling the Alarm

Models: SCQ-041AP SCQ-041P

1 49
Download 49 pages 53.63 Kb
Page 41
Image 41

Chapter 5

3.A green light blinks on the “RESET” button LED.

4.The alarm output becomes TTL “LOW” level.

5.The alarm is disabled automatically after the alarm reset time is reached.

NOTE

You can set the “ALARM RESET TIME” value in the “ALARM SET” menu.

6.When several alarms are on at the same time, all alarms stop when the alarm reset time is reached.

7.Press the “RESET” button to disable the alarm manually.

8.When the alarm is disabled, the alarm output becomes TTL “HIGH” level.

9.When the alarm is disabled, the alarm reset output is maintained for 150ms and then becomes TTL “HIGH” level.

10.The date, hour, and channel number of the relevant alarms are recorded in the alarm list.

NOTE

Press the “LIST” button to scan this information.

11. When the alarm is disabled, the screen displays the current mode.

Disabling the Alarm

While the alarm is on, you can either press the “RESET” button or wait for the alarm reset time to be reached to disable the alarm.

29

Page 41
Image 41
Samsung SCQ-041P, SCQ-041AP manual Disabling the Alarm