Samsung SHR-3010 System Setup, Communication Setup, ① PASSWORD, ② PASSWORD LOCK, ➂ HDD ERASE

Models: SHR-3010

1 45
Download 45 pages 45.83 Kb
Page 26
Image 26
System Setup

DIGITAL VIDEO RECORDER

GB

 

 

GB

 

9

8

 

 

System Setup

Communication Setup

The following illustrates the intial setting of the SYSTEM SETUP menu.

SYSTEM SETUP

PASSWORD

****

PASSWORD LOCK

OFF

HDD ERASE

OFF

FACTORY RESET

OFF

MENU SCREEN

DARK GRAY

LANGUAGE

ENGLISH

PASSWORD

Set the system password. You can enter a 4-digit number and the initial set value is 0000.

PASSWORD LOCK

If you set this to ON, you can ask for a password, which is set in the PASSWORD, each time the MENU button is pressed or the recording lock cancellation is attempted during the recording, and stop the respective operation if wrong password is entered. If set to OFF, you do not have to enter password for each case metioned above. [ON/OFF]

HDD ERASE

If you set to ON and exit the menu, the system will delete all data stored on the HDD.

[ON/OFF]

Communication Setup Caution

Verify once again that is is OK to delete the data, as deleted data cannot be restored.

FACTORY RESET

If you set to ON and finish the menu, all settings will be restored to their factory default set- tings. However, the data on the HDD will not be deleted. [ON/OFF]

MENU SCREEN

If this is set to DARK GRAY, the background of the screen becomes darker when the MENU button is pressed and you will not be able to see the characters clearly. If set to OFF, you can see the current video clearly even when the MENU button is pressed.

[DARK GRAY/OFF]

LANGUAGE (MULTI-LANGUAGE SUPPORT)

Besides English, multi-language support provides German, French, Italian, and Spanish. You can conveniently set the desired language. The default language is set to English.

[ENGLISH/DEUTSCH/FRANÇAIS/ESPAÑOL/ITALIANO]

The following illustrates the intial setting of the COMMUNICATION SETUP menu.

COMMUNICATION SETUP

BAUD RATE

115,200

 

NETWORK ACCESS

ON

 

 

 

IP ADDRESS

0.

0.

0.

0

GATEWAY

0.

0.

0.

0

SUBNET MASK

0.

0.

0.

0

NETWORK USER ID

****

 

 

 

NETWORK USER PWD

****

 

 

 

PAN/TILT TYPE

SCC-641

 

 

 

 

 

 

BAUD RATE

Sets data transmission rate in RS-232C communication.

[4,800/9,600/19,200/38,400/115,200]

NETWORK ACCESS/IP ADDRESS/GATEWAY/SUBNET MASK

If the system is connected to a LAN, it can be controlled from the remote surveillance pro- gram installed on a remote PC. To connect to a LAN, set the NETWORK ACCESS to ON, and configure the IP ADDRESS, GATEWAY, SUBNET MASK, etc. to suit the user’s net- work environment. Then, connect the LAN Cable to the LAN Cable connection terminal on the back of the system and reboot the system. If at least one from the IP ADDRESS, GATEWAY, and SUBNET MASK is modified, the system must be rebooted to apply the modified setting to the system.

NETWORK USER ID/NETWORK USER PWD

In order to access the system through a LAN from a remote surveillance program installed on a remote PC, the user ID and password must be entered. At this time, the user ID and password entered match the ones set in the NETWORK USER ID and NETWORK USER PWD, you can connect to the system; otherwise, you cannot gain access. Both are 4-digit numbers and the initial set values are 0000.

PAN/TILT TYPE (Remote Control of Camera)

The remote monitoring program installed in the PC can control Pan/Tilt/Zoom of the camera through the LAN cable. You shall choose a camera to be controlled. But the camera using the SEC protocol can be controlled. Please refer to the Remote Monitoring Program User’s Manual for the detailed camera control by the remote monitoring program.

3-23

3-24
Page 26
Image 26
Samsung SHR-3010 System Setup, Communication Setup, ① PASSWORD, ② PASSWORD LOCK, ➂ HDD ERASE, ➃ FACTORY RESET, ① BAUD RATE