Quality

Recording resolution will be determined. HH(Very High)/H(High)/N(Normal)/L(Low).

Note

The resolution Full D1 can be set from the 7.5ips(NTSC)/6.25ips(PAL) recording frame.

The resolution Halfl D1 can be set from the 15ips(NTSC)/12.5ips(PAL) recording frame.

The resolution CIF can be set from the 15ips(NTSC)/12.5ips(PAL) recording frame. But, if the resolution is CIF and the number of camera is odd number, 30ips(NTSC)/ 25ips(PAL) is supported.

Rate

Determines Frame Rate to be recorded. Frame Rate means the number of screen recorded every second.

Set to 15ips(NTSC)/12.5ips(PAL), the system records too many screens per sec- ond and play continues intermittently since recording is more detailed. This is appropriate for concentrated monitoring zone setup.

Set to the one of 30ips / 15ips / 10ips / 7.5ips / 5ips / 3ips / 1ips(NTSC)

Set to the one of 25ips / 12.5ips / 8.33ips / 6.25ips / 5ips / 2.5 ips / 1ips(PAL)

Pre-Event

Pre-Event Section

Event occurred point of time

Records the situation until Event is issued.

Off : No recording

5sec/ 10sec/ 20sec/ 30sec : The recording time options before Alarm issue

Post-Event

Post-Event Section

Event occurred point of time

Records the situation since Event is issued.

Off : No recording

5sec/ 10sec/ 20sec/ 30sec/1min/3min/5min/10min/20min :

To this, the recording time after Alarm issue is set.

5-20

Page 62
Image 62
Samsung SHR-4081P manual Quality, Pre-Event, Post-Event