SHR-4081N/P USER’S MANUAL

Alarm Detection Setup

Sensor State

Off : Sensor does not operate.

N.O(Normal Open) Sensor : Sensor remains open all the time and if closed, an alarm will be issued. (A Contact)

N.C(Normal Close) Sensor : Sensor remains closed all the time and if open, an alarm will be issued. ( B Contact)

Cam

Determines a camera which will synchronize with the current sensor.

The default is currently set to the sensor number. A sensor shall be synchronized with at least a camera. Multi-synchronization is possible.

Alarm-Out

Arranges Alarm-Out when Alarm Sensor sounds.

At this moment, this supports 5 Alarm Outs. Choose an alarm-out that you want to synchronize with the current sensor. Multi-choice is possible.

Beep-Out

Determines Alarm-Out Duration. Alarm-Out continues for the determined duration. Off/ 3sec/ 5sec/ 10sec/ 20sec/ 30sec