OSG Display
-Date: The date is displayed on the screen when it is set to On.
-Time: The time is displayed on the screen when it is set to On.
-Title: The camera name is displayed on the screen when it is set to On.
-Status: Recording and event information, Audio sign, and PTZ sign are displayed on the screen when it is set to On.
Spot Out Channel
This is used to monitor a specific channel by connecting a monitor to the SPOT jack on the rear of the product. When you are using two monitors, one monitor can be set for spot out monitoring. This provides two kinds of functions: Displaying the spot out channel only and auto sequencing of all channels.
-Auto sequence setup ranges from Ch 1 to Ch 16.
-In the auto sequence mode, channels are changed in turn.
-Duration period for auto sequence is the same as the one set in Camera Setup.
Spot Out Event Monitor
This is set for monitoring events from multiple channels.
-Off: The event monitoring does not operate in the Spot Out channel.
-3sec, 5sec, 10sec, 20sec, and 30sec: Sets the screen duration period in the Auto Sequence mode.
-Continuous: Once the event monitoring starts, the screen remains alive until you press the ALARM button.
Monitor Out
Video output methods can be selected from Composite, VGA, and Dual output modes. System restarts after changing the Video output methods.
-Composite video output: transfers the composite output signal.
-VGA video output: transfers VGA output signal.
-Dual video output: both the Composite and VGA video outputs are available to use.
PB Channel Position
You can designate the playback (PB) channel location in
Right Down: The playback channel is displayed at the lower right side of the screen. Center: The playback channel is displayed in the center of the screen.
Multi Channel Seq.
You can set the Auto Sequence interval for split screens. Available intervals are 3, 5, 10, 20, and 30 seconds.
[Video Out]
CAUTION You may experience low display quality while the dual video output is in use. In this case, please switch it to the composite or VGA video output. VGA video output port is not available while the composite video output is set to use and vice versa.
If the MODE and ZOOM buttons are pressed and hold for 5 seconds, the system restarts while alarming beep sound. The LED blinks while restarting and the video output mode is changed. (Composite output VGA output).
VGA output: 640x480 (60Hz)
RECORD MODE
The detailed list for record mode settings is as follows:
MENU SETUP
System |
|
| |
Camera |
|
| |
Monitoring |
|
| |
Record Mode | Record Quality & Auto Deletion | ||
Event Record | Record Rate & Video Size | ||
Event Record Duration | |||
Schedule | |||
|
| ||
Backup |
|
| |
Network |
|
| |
Move/Control | Select | MENU Exit |
Record Quality & Auto Deletion
Record Quality & Auto Deletion
Cam | Normal | Event | Cam | Normal | Event |
1 | Level4 | Level4 | 9 | Level4 | Level4 |
2 | Level4 | Level4 | 10 | Level4 | Level4 |
3 | Level4 | Level4 | 11 | Level4 | Level4 |
4 | Level4 | Level4 | 12 | Level4 | Level4 |
5 | Level4 | Level4 | 13 | Level4 | Level4 |
6 | Level4 | Level4 | 14 | Level4 | Level4 |
7 | Level4 | Level4 | 15 | Level4 | Level4 |
8 | Level4 | Level4 | 16 | Level4 | Level4 |
Auto Deletion: |
|
|
|
| |
Off | 01 Day |
|
| OK | Cancel |
menu setup _27
05 MENU SETUP
|
|