1_SMO-210TP_ENG 5/30/03 2:56 PM Page e-42

 

Chapter 7: Alarm, Motion, Loss and Door Bell

e-42

1. Alarm Occurrence

The Alarm becomes available only when an Alarm Box is connected.

1)When an Alarm trigger is received, a warning buzzer sounds and the screen is divided into 9 Live-Mode sub-screens. The word “EVENT” appears on the screen and the Alarm occurrence information is displayed at the right bottom of the screen.

02/06/01 12:30:01

EVENT

CH1 CH2 CH3

CH4 CH5 CH6

CH7

CH8

A 12345678

2)Press ENTER (in the middle of the Rotary Wheel) to replay the event in Event Replay mode. Up to 15 screens can be replayed centering on the time of the Alarm. The duration of Replay is displayed in a graph.

Turn the Rotary Wheel during the Replay to forward or reverse the stored screens one by one.

Press ENTER to terminate the Event Replay. The Event Replay will continue until ENTER has been pressed.

 

02/06/01

12:30:01

 

1

 

EVENT

CH1

CH2

CH3

 

CH4

 

CH5

CH6

 

 

 

ALARM

 

 

 

02/06/01

CH7

 

CH8

12:29:30

3)Alarm occurrence information is stored in the “EVENT LIST”.

4)Alarm Out (HOT, COLD) signals are active during the “ALARM HOLD TIME. ”

ALARM HOLD TIME : Time during which the Alarm function is carried on after the Alarm is first detected. Alarm Hold Time is reset automatically when Event Replay is turned on.