installation and external connection

CONNECTING TO THE EXTERNAL READER

External Reader Connection

Reader

DATA-0 (pink)

DATA-1 (sky blue)

DC12V (red)

GND (black)

GND (-)

OK Signal Out

Wiegand D0

CONTROLLER

Wiegand D1

Error Signal Out

DC12V

(+)

POWER

Power Supply Unit

1.Connect the DC 12V(+) line of the power supply unit to the plus (+) line of the reader.

2.Connect the GND(-) line of the power supply unit to the minus (-) line of the reader.

3.Connect the Wiegand DATA-0 line of the proximity reader to the pink line.

4.Connect the Wiegand DATA-1 line 1 of the proximity reader to the sky blue line

5.The product should be connected to GND(-) of the external reader.

For a list of compliant readers (external readers), see the followings:

SSA-R2010/SSA-R2020/SSA-R2040

- Standard 26bit Wiegand format proximity reader

SSA-R2011 / SSA-R2021 / SSA-R2041

- Standard 34bit Wiegand format proximity reader

16_ installation and external connection

Page 16
Image 16
Samsung SSA-R2010/EXP manual Connecting to the External Reader, External Reader Connection