Sanyo DTL-4800 Output Terminals, TAPE END OUT Terminal, WARNING OUT Terminal, TIMER OUT Terminal

Models: RD2QD/NA DTL-4800

1 57
Download 57 pages 41.55 Kb
Page 50
Image 50
OUTPUT TERMINALS

OUTPUT TERMINALS

TAPE END OUT Terminal

œDuring recording, when the end of the tape is reached or when approximately 5% of the tape remains, the output becomes 0V (Low).

œTo reset the output, press the STOP or EJECT button.

œDuring autorepeat recording, when the end of the tape is reached, the output becomes 0V (Low) for about 2 seconds only.

End of the tape or approximately 5% of the tape remaining Output reset

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

TAPE END OUT Terminal Output Setting

1Press the MENU button to display the (MAIN MENU 1) menu.

2Press the SHIFT ] button to select the “4. VARIOUS SET 1” line, then press the MENU button.

øThe (VARIOUS SET 1) menu appears.

@@@@<VARIOUS@SET@1>

*THREAD@CHECK@@@@Y

*REMOTE@@@@@@@@@@EJECT

*EXT@TIME@ADJ.@@@01:00

*TAPE@END@OUT@@@@PRE

*EJECT@SET

@@EJECT@MODE@@@@@EJECT1

@@OPERATION@@@@@@SLAVE

3Press the SHIFT ] (or \) button, until the “TAPE END OUT” setting is flashing.

4Press the DATA l (or j) button to select the desired output mode.

PRE . . . . . . . The output becomes 0 V (Low) when approximately 5% of the tape remains (if recording has been started at the beginning of the tape) and/or when the end of the tape is reached (if recording has not been started at the beginning of the tape).

END . . . . . . . The output becomes 0 V (Low) when the tape reaches the end.

5Press the MENU EXIT button to save the setting.

WARNING OUT Terminal

œIf the tape stops or other problem (the heads are dirty, there is a problem with the battery or the cooling fan, etc.) the output becomes 0V (Low).

œTo reset the output, press the STOP or ALL RESET button or unplug the power cord then plug it back in.

Tape movement stop

Output reset

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

NOTE:

œIf the output is 0V (Low) due to the clog detect function, it can be reset by simply pressing the STOP button.

TIMER OUT Terminal

œDuring timer recording DC 12 V (High) are output. (During timer recording stand-by mode, the output is 0V (Low).)

Timer recording

12V (H)

(Output impedance: 5.7 kΩ) 0V (L)

COM Terminal

œCommon GND (ground) terminal when connecting other terminals to external devices.

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT terminal.

This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.

TAPE END OUT Terminal FIELD: 16.7 msec.

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

English

49

Page 50
Image 50
Sanyo DTL-4800, RD2QD/NA Output Terminals, TAPE END OUT Terminal, WARNING OUT Terminal, TIMER OUT Terminal, COM Terminal