2-2-2. Outdoor Unit
Outdoor Unit
Control PCB |
|
| |||
|
|
|
|
|
|
| Part No. |
| |||
| Controls |
| Microprocessor | ||
| Control Circuit Fuse |
| 250V 25A | ||
|
|
|
|
| |
Compressor |
|
| |||
|
|
|
|
|
|
| Type |
| DC Twin Rotary (Hermetic) | ||
| Compressor Model / Nominal Output |
| |||
| Compressor Oil ... Amount | CC | FV50S ... 350 | ||
| Coil Resistance (Ambient Temp. 20 oC) | Ohm | R - S : 0.482 | ||
|
|
|
|
| S - T : 0.482 |
|
|
|
|
| T - R : 0.482 |
|
|
|
|
|
|
| Safety Device |
|
| ||
|
|
| CT (Peak current |
| Yes |
|
|
| Compressor Discharge Temp. Control |
| Yes |
|
|
| Operation | Yes | |
| Run Capacitor | Micro F | - | ||
|
|
|
| VAC | - |
| Crankcase Heater |
| - | ||
|
|
|
| ||
Fan |
|
| |||
|
|
|
|
|
|
| Type |
| Propeller | ||
| Q'ty ... Dia. | mm | 1 ... D420 | ||
|
|
|
| ||
Fan Motor |
|
| |||
|
|
|
|
|
|
| Type |
| DC Motor | ||
| Model ... Q'ty |
| |||
| No. of Poles |
| 8 | ||
| Rough Measure RPM (Cool / Heat) |
| 750 / 750 | ||
| Nominal Output | W | 50 | ||
| Coil Resistance | Ohm | RED - WHT : 77.5 | ||
| (Ambient Temp. 20 oC) |
| WHT - BLU : 77.5 | ||
|
|
|
|
| BLU - RED : 77.5 |
| Safety Device |
|
| ||
|
| Type |
| Internal Controller | |
|
| Over- Current Protection |
| Yes | |
| Run Capacitor | Micro F | - | ||
|
|
|
| VAC | - |
|
|
| |||
Heat Exchanger Coil |
|
| |||
|
|
|
|
|
|
| Coil |
| Aluminum Plate Fin / Copper Tube | ||
| Rows |
| 2 | ||
| Fin Pitch | mm | 1.3 | ||
| Face Area | m2 | 0.452 | ||
|
|
|
|
| |
External Finish |
| Acrylic |
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
10