Sanyo SAP-KRV94EHDX Unit Specifications, Voltage Rating, Performance, Electrical Rating

Models: SAP-KRV94EHDX

1 85
Download 85 pages 37.36 Kb
Page 6
Image 6

2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit SAP-KRV94EHDX

Outdoor Unit SAP-CRV94EHDX

Voltage Rating

 

 

 

 

 

230 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

Cooling

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

 

kW

2.65

( 0.9 to 3.8 )

 

3.60

( 0.9 to 5.5 )

 

 

 

 

 

BTU/h

9,000

( 3,100 to 13,000 )

 

12,300

( 3,100 to 18,800 )

 

 

 

 

 

 

 

 

 

 

 

 

Air Circulation (High)

 

 

 

m3/h

 

600

 

 

600

 

Moisture Removal (High)

 

 

Liters/h

 

1.8

 

 

-

 

 

 

 

 

 

 

 

 

 

Electrical Rating

 

 

 

 

 

Cooling

 

 

Heating

 

 

 

 

 

 

 

 

 

 

Available Voltage Range

 

 

V

 

198

to 264

 

 

Running Amperes

 

 

 

A

2.40

( 1.6 to 6.9 )

 

3.30

( 1.6 to 9.9 )

 

Power Input

 

 

 

W

530

( 250 to 1,350 )

 

720

( 250 to 1,450 )

 

Power Factor

 

 

 

%

 

96

 

 

95

 

E.E.R.

 

 

 

W/W

 

5.0

 

 

-

 

C.O.P.

 

 

 

W/W

 

-

 

 

5.0

 

Compressor Locked Rotor Amperes

 

 

A

 

 

 

7.8

 

 

 

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls / Temperature Control

 

 

 

 

Microprocessor / I.C. Thermister

 

Control Unit

 

 

 

 

 

Wireless Remote Control Unit

 

Timer

 

 

 

 

24-Hour ON or OFF Timer, 1.2.3.5-Hours OFF Timer

 

Fan Speeds

 

Indoor / Outdoor

 

Auto and 3 steps

 

Airflow Direction (Indoor)

 

 

Horizontal

 

 

Auto

 

 

 

 

 

 

Vertical

 

 

Auto

 

 

Air Filter

 

 

 

 

 

Washable, Anti-Mold

 

Compressor

 

 

 

 

 

DC Twin Rotary (Inverter)

 

Refrigerant / Amount charged at shipment

g

 

R410A / 1,380

 

 

Refrigerant Control

 

 

 

 

 

Electric Expansion Valve

 

Operation Sound

Indoor : Hi/Me/Lo/Qt*

dB-A

39 / 38 / 30 / 22

 

 

40 / 38 / 30 / 22

 

(*Qt = Quiet mode)

Outdoor : Hi

 

 

dB-A

 

49

 

 

50

 

 

 

 

 

 

 

 

 

 

Refrigerant Tubing Connections

 

 

 

 

Flare

Type

 

 

Max. allowable tubing length at shipment

m

 

 

7.5

 

 

Refrigerant

Narrow tube

 

 

mm (in.)

 

6.35 (1/4)

 

 

Tube Diameter

Wide tube

 

 

mm (in.)

 

9.52 (3/8)

 

 

Refrigerant Tube Kit / Accessories

 

 

 

 

Optional / Air Clean Filter

 

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

 

 

Indoor Unit

 

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

Unit Dimensions

Height

 

 

mm

 

300

 

 

569

 

 

Width

 

 

mm

 

898

 

 

790

 

 

Depth

 

 

mm

 

200

 

 

285

 

Package Dimensions

Height

 

 

mm

 

280

 

 

645

 

 

Width

 

 

mm

 

970

 

 

921

 

 

Depth

 

 

mm

 

360

 

 

386

 

Weight

Net

 

 

kg

 

12.5

 

 

40.0

 

 

Shipping

 

 

kg

 

14.0

 

 

43.0

 

Shipping Volume

 

 

 

m3

 

0.098

 

 

0.229

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks: Rating conditions are:

 

 

 

 

 

 

 

 

 

Cooling: Indoor air temperature

27°C D.B. / 19°C W.B.

 

 

 

 

 

Outdoor air temperature

35°C D.B. / 24°C W.B.

 

 

 

 

 

Heating: Indoor air temperature

20°C D.B.

 

 

 

 

 

 

Outdoor air temperature

7°C D.B. / 6°C W.B.

 

 

 

 

6

Page 6
Image 6
Sanyo SAP-KRV94EHDX Unit Specifications, Voltage Rating, Performance, Electrical Rating, Features, Dimensions & Weight