2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit
Outdoor Unit
Voltage Rating |
|
|
|
|
| 230 V |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Performance |
|
|
|
|
| Cooling |
|
| Heating | |
|
|
|
|
|
|
|
|
|
|
|
| Capacity |
|
|
| kW | 2.65 | ( 0.9 to 3.8 ) |
| 3.60 | ( 0.9 to 5.5 ) |
|
|
|
|
| BTU/h | 9,000 | ( 3,100 to 13,000 ) |
| 12,300 | ( 3,100 to 18,800 ) |
|
|
|
|
|
|
|
|
|
|
|
| Air Circulation (High) |
|
|
| m3/h |
| 600 |
|
| 600 |
| Moisture Removal (High) |
|
| Liters/h |
| 1.8 |
|
| - | |
|
|
|
|
|
|
|
|
|
| |
Electrical Rating |
|
|
|
|
| Cooling |
|
| Heating | |
|
|
|
|
|
|
|
|
| ||
| Available Voltage Range |
|
| V |
| 198 | to 264 |
| ||
| Running Amperes |
|
|
| A | 2.40 | ( 1.6 to 6.9 ) |
| 3.30 | ( 1.6 to 9.9 ) |
| Power Input |
|
|
| W | 530 | ( 250 to 1,350 ) |
| 720 | ( 250 to 1,450 ) |
| Power Factor |
|
|
| % |
| 96 |
|
| 95 |
| E.E.R. |
|
|
| W/W |
| 5.0 |
|
| - |
| C.O.P. |
|
|
| W/W |
| - |
|
| 5.0 |
| Compressor Locked Rotor Amperes |
|
| A |
|
|
| 7.8 |
| |
|
|
|
|
|
|
|
|
|
| |
Features |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||||
| Controls / Temperature Control |
|
|
|
| Microprocessor / I.C. Thermister | ||||
| Control Unit |
|
|
|
|
| Wireless Remote Control Unit | |||
| Timer |
|
|
|
| |||||
| Fan Speeds |
| Indoor / Outdoor |
| Auto and 3 steps | |||||
| Airflow Direction (Indoor) |
|
| Horizontal |
|
| Auto |
| ||
|
|
|
|
| Vertical |
|
| Auto |
| |
| Air Filter |
|
|
|
|
| Washable, | |||
| Compressor |
|
|
|
|
| DC Twin Rotary (Inverter) | |||
| Refrigerant / Amount charged at shipment | g |
| R410A / 1,380 |
| |||||
| Refrigerant Control |
|
|
|
|
| Electric Expansion Valve | |||
| Operation Sound | Indoor : Hi/Me/Lo/Qt* | 39 / 38 / 30 / 22 |
|
| 40 / 38 / 30 / 22 | ||||
| (*Qt = Quiet mode) | Outdoor : Hi |
|
|
| 49 |
|
| 50 | |
|
|
|
|
|
|
|
|
| ||
| Refrigerant Tubing Connections |
|
|
|
| Flare | Type |
| ||
| Max. allowable tubing length at shipment | m |
|
| 7.5 |
| ||||
| Refrigerant | Narrow tube |
|
| mm (in.) |
| 6.35 (1/4) |
| ||
| Tube Diameter | Wide tube |
|
| mm (in.) |
| 9.52 (3/8) |
| ||
| Refrigerant Tube Kit / Accessories |
|
|
|
| Optional / Air Clean Filter | ||||
|
|
|
|
|
|
|
|
|
| |
Dimensions & Weight |
|
|
|
|
| Indoor Unit |
|
| Outdoor Unit | |
|
|
|
|
|
|
|
|
|
|
|
| Unit Dimensions | Height |
|
| mm |
| 300 |
|
| 569 |
|
| Width |
|
| mm |
| 898 |
|
| 790 |
|
| Depth |
|
| mm |
| 200 |
|
| 285 |
| Package Dimensions | Height |
|
| mm |
| 280 |
|
| 645 |
|
| Width |
|
| mm |
| 970 |
|
| 921 |
|
| Depth |
|
| mm |
| 360 |
|
| 386 |
| Weight | Net |
|
| kg |
| 12.5 |
|
| 40.0 |
|
| Shipping |
|
| kg |
| 14.0 |
|
| 43.0 |
| Shipping Volume |
|
|
| m3 |
| 0.098 |
|
| 0.229 |
|
|
|
|
|
|
| DATA SUBJECT TO CHANGE WITHOUT NOTICE. | |||
Remarks: Rating conditions are: |
|
|
|
|
|
|
|
| ||
| Cooling: Indoor air temperature | 27°C D.B. / 19°C W.B. |
|
|
|
| ||||
| Outdoor air temperature | 35°C D.B. / 24°C W.B. |
|
|
|
| ||||
| Heating: Indoor air temperature | 20°C D.B. |
|
|
|
|
| |||
| Outdoor air temperature | 7°C D.B. / 6°C W.B. |
|
|
|
|
6