7-2. Recommended Wire Length and Diameter

7-2. Recommended Wire Length and Diameter

Regulations on wiring diameter differ from locality to locality. For field wiring requirements, please refer to your local electrical codes. Carefully observe these regulations when carrying out the installation.

Table 2 lists recommended wire lengths and diameters for power supply systems.

NOTE

Refer to the wiring system diagram (Fig. 6) for the meaning of (A), (B) and (C) in Table 2.

Table 2

Cross-Sectional

(A)+(B)

(A) Power Supply Wiring Length (m)

(C) Control

Fuse or Circuit

Area (mm2)

 

(B) Power Line Length (m)

Line Length (m)

Model

2

3.5

2

Breaker Capacity

 

CRV94

33

51

20

15A

CRV124

33

51

20

 

WARNING

Manual background Be sure to comply with local codes on running the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc.).

Manual background Each wire must be firmly connected.

Manual background No wire should be allowed to touch refrigerant tubing, the compressor, or any moving part.

WARNING

Manual background To avoid the risk of electrical shock, each air conditioner unit must be grounded.

Manual background For the installation of a grounding device, please observe local electrical codes.

Manual background Grounding is necessary, especially for units using inverter circuits, in order to release charged electricity and electrical noise caused by high tension. Otherwise, electrical shock may occur. Manual background Place a dedicated ground more than 2 meters away from other grounds and do not have it shared with other electric appliances.

CAUTION

Manual background Be sure to connect the power supply line to the indoor unit as shown in the wiring diagram. The outdoor unit draws its power from the indoor unit.

Manual background Do not run wiring for antenna, signal, or power lines of television, radio, stereo, telephone, security system, or intercom any closer than 1 meter from the power cable and wires between the indoor and outdoor units. Electrical noise may affect the operation.

WIRING SYSTEM DIAGRAM

Power supply

Indoor Unit

Outdoor Unit

Single-phase 50Hz Terminal

Terminal

220 to 240VAC

(B)

 

 

1

 

1

 

2

2

 

3

3

 

(C)

4

(A)

Grounding line

 

 

Grounding line

Fig. 6

24

Page 24
Image 24