E-mail setting

Examples: Type and contents of alert mail

When the projector has an abnormality, the following alert messages are sent to the registered E-mail address depending on your selected condition. Administrator or user can take an efficient action quickly by receiving this message. This is very useful to maintain and service the projector.

The following are examples of received messages.

When internal PJ temperature is too high:

TITLE: Message from projector 10-03-2007 00:59

Projector Model Name: model name

TCP/IP: 192.168.1.201 Projector Name: Proj05

It sends you following message.

*The Projector lamp is turned off, because internal Projector temperature is too high. Wait for the completion of the cooling process and make sure the projector has been turned into Standby. Then turn the projector on again.

If the Indicator continues flashing, check the air filter for dust accumulation.

[A]81.5 degrees fahrenheit [B] 134 degrees fahrenheit [C] 95.6 degrees fahrenheit Temperature of Sensor B is too high.

The projector let users know the information which thermal sensors inside the projector detected the abnormal temperature risen and so the projector was turned off. Please refer to item "Power control and status check" (p.64) for the location of the sensors and each temperature . Also see the owner's manual of the projector for further details.

When internal PJ power circuit is failed:

TITLE: Message from projector 10-03-2007 00:59

Projector Model Name: model name

TCP/IP: 192.168.1.201 Projector Name: Proj05

It sends you following message.

*The Projector lamp is turned off, because Projector power circuit is failed.

Unplug the Projector from AC outlet and ask servicing to qualified service personnel.

MAIN,

ALL

OK

 

FAN,

5V

OK

Error information

MCI,

3.3V

NG

 

The projector lamp was turned off, because the projector power circuit failed.

Unplug the projector from AC outlet and contact a qualified service personnel for service with the error information.

57

Page 57
Image 57
Sanyo QXXAVC922---P, SO-WIN-KF3AC owner manual Examples Type and contents of alert mail