1 In [CLOCK ADJUST], select “ON (NTP)”.

2 Configure the required settings shown below and click SET .

1To automatically adjust the clock time every day, in [TIME TO SYNCHRONIZE], select the 24-hour time to which you want to adjust the clock (for example, “10:30”).

2To adjust the clock to the current time, click REFRESH .

3In [NTP SERVER ADDRESS], type the IP address or domain name of the NTP server from which you want to retrieve the date and time information.

4In [LOG], the last entry of the operation log related to automatic clock adjustment is shown.

When “ON (NTP)” in [CLOCK ADJUST] is selected, the clock adjustment function adjusts the clock in the following timings.

When the camera is turned on

At the time selected in [TIME TO SYNCHRONIZE] (every day)

When any change is made to the settings on this screen

To use a domain name, you must specify the DNS server address in [DNS SERVER ADDRESS] on the NETWORK SETTINGS screen.

1 In [CLOCK ADJUST], select “ALARM IN1”.

2 In [CLOCK IN], select the 24-hour time to which you want to adjust the clock (for example, “22” for 10 p.m.) when the switch connected to the ALARM IN1 terminal turns on, and click SET .