If no directory name is specified, the system will automatically generate the following directory name.

When sending an alarm image in the event of an error: ALARM_FTP

When sending an image in fixed intervals: INTERVAL_FTP

6 In [FILE NAME], specify the name of the image file you want to send and click SET .

You can type up to 32 alphanumeric characters.

Each image file will have a file name consisting of the specified file name, the date/time, and the alarm factor (if [TRIGGER] is set to other than “INTERVAL”):

[FILE NAME] + [yy_mm_dd_hh_mm_ss] + [alarm_factor] + [0001 (Serial No.).jpg]

If no file name is specified, the system will enter “sanyo” for the [FILE NAME].

* To use a temporary file, set [TEMPORARY FILE] to “USE”.

This causes each image to be stored as a temporary file on the FTP server and then renamed to the specified file name.

The FTP server will store a single temporary file for the most recent image with the specified file name.

Temporary file name: sanyo_ftp_temp_[IP address].temp

Although the temporary file will be renamed to the specified file name and then stored in the specified directory as explained in steps 5 to 6 , the renamed file name will not include the date/time and alarm factor information.

Both the temporary and permanent files will be overwritten if the same file name exists.

In [TRIGGER], select the image transmission trigger condition, configure items as necessary and click SET .

INTERVAL: Sends a still image in fixed intervals.

ALARM IN1: Sends a still image when the ALARM IN1 terminal receives an alarm signal.

ALARM IN2: Sends a still image when the ALARM IN2 terminal receives an alarm signal.

MOTION: Sends a still image when the motion sensor detects motion in the subject.

ALARM OUT1: Sends a still image when the ALARM OUT 1 terminal outputs an alarm signal.

ALARM OUT2: Sends a still image when the ALARM OUT 2 terminal outputs an alarm signal.

NETWORK FAILURE: Sends a still image when the camera detects a network failure during network recording.

You need to configure the alarm input/output conditions on the ALARM SETTINGS screen.

A If you selected “NETWORK FAILURE” ...

In [NETWORK FAILURE TIME], select the time from the occurrence of a network failure until the camera recognizes it as a recording trigger.

15SEC, 20SEC, 30SEC, 40SEC, 50SEC, 1MIN, 2MIN, 3MIN, 4MIN, 5MIN

Working with Administrator Configuration Screens 44/50

Page 92
Image 92