Sanyo VDC-HD3100/HD3100P, VDC-HD3300/HD300P specifications Quick Operation Guide 6/10

Models: VDC-HD3100/HD3100P VDC-HD3300/HD300P

1 116
Download 116 pages 37.31 Kb
Page 21
Image 21

BDetecting motion in specific areas

In [MOTION], after selecting a motion sensor type, click DETAIL to configure the detection conditions on the detailed configuration screen.

You can configure the camera to “automatically output alarm signals” or “remotely (manually) output alarm signals”.

You can configure the camera to automatically output an alarm signal when either of its alarm input terminals receives an alarm signal.

Setting Item

Default Setting

 

 

ALARM OUT1/ 2 (Alarm

OFF (Disables alarm output.)

output terminal number)

 

 

 

POLARITY (Signal polarity)

NO

 

 

ALARM OUT TIME (Alarm

5SEC (Ex.: Beeps a warning for 5 sec.)

output time)

 

 

 

ALARM IN (Output

ALARM IN1 (Triggers alarm output when

ALARM IN1 terminal receives an alarm

condition)

signal.)

 

 

 

MOTION (Output condition)

OFF (Disables alarm output using motion

sensor.)

 

 

 

Optional Setting

ON (Enables automatic alarm output.)

NC

10SEC to 5MIN

ALARM IN2 (Triggers alarm output when ALARM IN2 terminal receives an alarm signal.)

ON (Triggers alarm output using motion sensor.)

Use the Remote Alarm buttons () provided on the live screen to send alarm signals from the camera's alarm output terminals.