Schneider Optics Modicon Quantum Ethernet manual Reading and Writing Registers, Read Register Box

Models: Modicon Quantum Ethernet

1 105
Download 105 pages 29.91 Kb
Page 61
Image 61

Using the Network Options Ethernet Tester

5.5Reading and Writing Registers

To read registers, select Messages and chose Read Registers from the pulldown menu or click on the read register button in the toolbar.

Figure 23 Read Register Box

Type in a polling interval, the first 4x register you want to read and the number of registers to read. The polling interval is the number of seconds between transactions. When typing the 4x register number, omit the leading 40 or 400, as in Figure 23 above.

Click OK. The register values will be displayed in the window for this connection. Five values will be listed in each row, with the number of the first register at the beginning of the row.

To write registers, select Messages and choose Write Registers from the pulldown menu or click on the write register button in the toolbar.

Type in a polling interval, the first register you want to write, the number of registers to write and data to be written to those registers. The polling interval is the number of seconds between transactions. When typing the 4x register number, omit the leading 40 or 400, as in Figure 24 below.

If you select the Increment Write Data box, the value of the data you have entered will be increased by one with each transaction. The write data will be displayed in the window for this connection.

840 USE 115 00 Version 1.0

51

Page 61
Image 61
Schneider Optics Modicon Quantum Ethernet manual Reading and Writing Registers, Read Register Box