Sega 999-1108 owner manual Troubleshooting, Problems Cause Countermeasures, Circuit Protector

Models: 999-1108

1 118
Download 118 pages 52.74 Kb
Page 78
Image 78

15. TROUBLESHOOTING

In order to prevent electric shock and short circuit, be sure to turn power off before performing work.

Be careful so as not to damage wirings. Damaged wiring can cause electric shock or short circuit.

After removing the cause of the functioning of the Circuit Protector, reinstate the Circuit Protector. Depending on the cause of the functioning, using the Circuit Protector as is without removing the cause can cause generation of heat and fire hazard.

In case a problem occurs, first check wiring connector connections.

TABLE 15 a

PROBLEMS

 

CAUSE

COUNTERMEASURES

 

 

 

 

 

 

With Main SW ON,

Power is not supplied.

Securely insert the power plug into the

no activation.

 

 

 

plug socket.

 

Power supply/voltage is not correct.

Make sure that power supply/voltage is

 

 

 

 

correct.

 

The Circuit Protector functioned

 

 

 

due to the momentary overload.

After eliminating the cause of overload,

 

 

 

 

reinstate the AC Unit's Circuit Protector

 

 

 

 

(see 4 , Sec. 5, Refer to the following).

 

 

 

 

Reset the circuit protector on the ASSY

 

 

 

 

ELEC. (see PHOTO 15 a, b)

 

 

 

 

 

 

The color on PTV

Image adjustment is inappropriate.

Adjust appropriately.

screen is incorrect.

 

 

 

 

 

 

 

 

 

 

 

Color deviation on

Affected by peripheral machines or

Perform convergence adjustment

monitor screen.

the building's steel frames.

 

 

 

 

 

 

Change installation direction or position.

 

 

 

 

Move the machine which causes the

 

 

 

 

problem.

 

 

 

No sound is emitted.

Sound volume adjustment is not

Adjust sound volume (see Sec. 8).

 

appropriate.

 

 

 

Board and Amplifier

Perform the sound test and confirm

 

malfunctioning.

(see Sec. 8).

 

 

 

 

 

 

 

 

 

 

CIRCUIT PROTECTOR

 

 

 

 

 

 

CIRCUIT PROTECTOR

 

 

 

 

Functions due to the activation of bimetal. To restore the function, wait for approximately one minute or longer until the bimetal cools off. (Press the Button.)

FIG. 15

71

Page 78
Image 78
Sega 999-1108 owner manual Troubleshooting, Problems Cause Countermeasures, Circuit Protector