Setup Parameter

Values

Description

 

 

 

INTERFACE TYPE

parallel, serial, automatic,

Selects the interface type. In case of ‘automatic’ the interface

 

auto+blink

type is selected by the printer depending on data coming from

 

 

host. When the auto+blink item is selected, the P1 and P2

 

 

leds blink to indicate which interface is selected: P1 blinks

 

 

when the parallel interface is selected, whereas P2 blinks,

 

 

when the serial interface is selected.

 

 

 

INPUT BUFFER

1 Kb, 8 Kb, 16 Kb, 32 Kb

Selects the buffer size.

 

 

 

IGNORE PE

enabled, disabled

Selects whether the printer signals the paper empty condition

 

 

(disabled) or not (enabled).

 

 

 

AUTOFEED SIGNAL

disabled, enabled

The parallel interface uses (enabled) or does not use

 

 

(disabled) the AUTOFEED signal.

 

 

 

SLCT-IN SIGNAL

disabled, enabled

The parallel interface uses (enabled) or does not use

 

 

(disabled) the SELECT-IN signal.

 

 

 

BUFFER CONTROL

DTR+SRTS, SRTS,

Selection of the buffer protocol.

 

XON/XOFF,

 

 

XON/XOFF+DTR+SRTS

 

 

 

 

ROBUST XON

enabled, disabled

Perform the Robust XON (enabled) or not (disabled).

 

 

 

WORD LENGTH

7 bit, 8 bit

Sets the number of the data bits.

 

 

 

BAUD RATE

600 - 38400 bps

Sets the data transfer rate.

 

 

 

PARITY BIT

even, odd, none

Selects the parity control for the data.

 

 

 

34