Removing and Installing the Lamp Unit

Removing and Installing the Lamp Unit

OptionalWarning!

Do not remove the lamp unit from the projector right after use. The lamp and parts around the lamp will be very hot and may cause burns or injury.

Optional

accessory

Lamp unit

AN-SV10LP

2 Disconnect the power cord. Info

Do not touch the glass surface of the lamp unit or the inside of the projector.

To avoid injury to yourself and damage to the lamp, make sure you carefully follow the steps below.

Do not loosen other screws except for the lamp unit cover and lamp unit.

1 Press STANDBY/ON on the projector or STANDBY on the remote control to put the projector into Standby mode.

23Remove the lamp unit cover.Manual background Disconnect the power cord.

Unplug the power cord from the AC socket.

Leave the lamp until it has fully cooled Manual background down (about 1 hour).

3Remove the lamp unit cover.

Loosen the user service screw (1) that

secures the lamp unit cover. Remove the lamp unit cover (2).

STANDBY/ON Manual backgroundManual background buttonManual backgroundManual backgroundManual background

AC socket

User service screw (for lamp unit cover)