Issue A1 5 System Parameters
MICROMASTER 410 Operating Instructions
6SE6400-5EA00-0BP0 51
5.3 Parameter List (short form)
Explanatory information on following table:
Ø Default: Factory setting
Ø Level: Access level (Acc)
Ø DS Inverter status (Drive State), indicates the inverter state in which a
parameter can be modified (see P0010).
C Commissioning
URun
T Ready to run
Ø QC Quick Commissioning
Q Parameter can be modified in the Quick Commissioning state.
N Parameter cannot be modified in the Quick Commissioning state.

Always

ParNr ParText Default Acc DS QC
r0000 Drive display - 1 - -
P0003 User access level 1 1 CUT N
P0004 Parameter filter 0 3 CUT N
P0010 Commissioning parameter filter 0 1 CT N

Quick Commissioning

ParNr ParText Default Acc DS QC
P0100 Europe / North America 0 1 C Q
P0101 Hidden Switch Setting 0 1 C Q
P3900 End of quick commissioning 0 1 C Q

Parameter Reset

ParNr ParText Default Acc DS QC
P0970 Factory reset 0 1 C N

Inverter Unit (P0004 = 2)

ParNr ParText Default Acc DS QC
r0018 Firmware version - 3 - -
r0026 CO: Act. DC-link voltage - 2 - -
r0206 Rated inverter power [kW] / [hp] - 3 - -
r0207 Rated inverter current - 3 - -
r0209 Maximum inverter current - 3 - -
P0210 Supply voltage 230 3 CT N
P0290 Inverter overload reaction 2 3 CT N
P1800 Pulse frequency 4 3 CUT N