Circuit Switch Communications

Commands Specific to the Raven 1x C3210 and C3216

The command string cannot contain any spaces, commas, the plus (+) symbol, or a semi‐colon (;). If an AT command needed for the string contains a plus or comma (for example, +IFC=0,0), you will need to designate a break character since you cannot use the standard break of ; for the plus to be read and a replacement for the comma. The break and comma designations need to be at the end of the *PTINIT command and separated with commas. During the INIT sequence, the modem looks at the entire command before executing the AT command string. If there are replacement values, it will perform the appropriate replacement before executing the AT command.

Table 2-1: Example for the Raven C3210 and C3216

CommandComponents

AT*PTINIT=AT&C1S0=1$QCVAD=4%+IFC=0^0,%,^ AT*PTINIT=

Include this portion only if you will not be entering the command using a AceManager. The remainder of the example is the command string.

AT

All AT commands must start with “AT”.

&C1S0=1$QCVAD=4%+IFC=0^0

The string is a combination of AT Commands limited to a maximum of 40 characters.

,% [,break]

Optional “BREAK” character to allow the use of a command with a “+”. In the example, a “%” is used.

,^ [,comma]

Optional comma replacement character to allow the use of a command requiring a comma. In the example, a ^ is used.

Commands Specific to the Raven 1x C3211

No special characters are needed for BREAK and comma though some commands will require a ‘line break’, ;AT.

 

 

 

 

 

 

 