English

Self-diagnosis display

Your camcorder has a self-diagnosis display function.

This function displays the current condition of your camcorder as a 5-digit code (a combination of a letter and figures) in the viewfinder, on the LCD screen or in the display window. If a 5-digit code is displayed, check the following code chart. The last two digits (indicated by ￿￿) will differ depending on the state of your camcorder.

Viewfinder (or LCD screen)

C:21:00

Self-diagnosis display

•C:￿￿:￿￿

You can service your camcorder yourself.

•E:￿￿:￿￿

Contact your Sony dealer or local authorized Sony facility.

Five-digit display

Cause and/or Corrective Actions

C:04:￿￿

• You are using a battery pack that is not an “InfoLITHIUM”

 

battery pack.

 

mUse an “InfoLITHIUM” battery pack. (p. 17)

C:21:￿￿

• Moisture condensation has occurred.

 

mRemove the cassette and leave your camcorder for at least 1

 

hour to acclimatize. (p. 131)

C:22:￿￿

C:31:￿￿

C:32:￿￿

E:61:￿￿

E:62:￿￿

• The video heads are dirty.

mClean the heads using the Sony V8-25CLD cleaning cassette (not supplied). (p. 132)

A malfunction other than the above that you can service has occurred.

mRemove the cassette and insert it again, then operate your camcorder.

mDisconnect the mains lead of the AC power adaptor or remove the battery pack. After reconnecting the power source, operate your camcorder.

A malfunction that you cannot service has occurred.

mContact your Sony dealer or local authorized Sony service facility and inform them of the 5-digit code. (example: E:61:10)

If you are unable to rectify the problem even if you try corrective actions a few times, contact your Sony dealer or local authorized Sony service facility.

122