4-1 Preparations for Recording

Time Code Locking of Two or More DVW- 250/250P Units

Connect the DVW-250/250P units as shown in the figure below.

In this case, on each of the DVW-250/250P units, set the F-RUN/R-RUN switch to F-RUN and the CONFI switch to ECC or OFF.

Then set the first DVW-250/250P so that it outputs the time code generator signal from the TC OUT connector. For example, when the “TC OUT” item is set to “AUTO” (see previous page), the unit must be in the E-E mode.

Recording 4 Chapter

Reference signal

REF IN

 

Time code

 

 

 

 

generator

 

 

 

 

 

 

 

 

REF OUT

 

First DVW-250/250P

 

 

TC IN

Camera

GENLOCK IN

CAMERA

TC OUT

Second DVW-250/250P

TC IN

Camera

GENLOCK IN

CAMERA

TC OUT

Third DVW-250/250P

TC IN

Camera

GENLOCK IN

CAMERA

Example connections for time code locking

4-12Chapter 4 Recording