1 CONFI switch |
|
|
| ||
2 CUE REC switch |
|
|
| ||
3 |
| 6 +48 V | switches | ||
4 MONITOR |
|
| 7 CAMERA/LINE switches | ||
SELECT switches | |||||
5 PHONE |
|
| 8 Audio input level switches | ||
LEVEL control knob |
|
9 AUDIO IN connectors
0 AUDIO OUT connectors !¡ EARPHONE jack
!™ HEADPHONES jack
Audio connectors and controls
Parts of Function and Location 2 Chapter
1CONFI (confidence) switch
This selects the mode for monitoring during recording. Note that this switch applies to both video and audio.
ON: Monitor the simultaneous playback of the recorded signals from the confidence heads.
ECC (Error Correcting Codes): Monitor the input signals unchanged (in
OFF: Monitor the input signals unchanged (in
The ON setting results in the highest power consumption, and the OFF setting the lowest. When using the unit with a battery pack, set the CONFI switch to the ECC or OFF position.
2CUE REC (record) switch
It is possible to mix the analog audio input signals and record them on the analog cue track on the tape. This switch determines whether or not to record on the cue track during normal recording. When this switch is in the ON position, channels 1 to 4 of the analog audio input are mixed and recorded on the cue track.
When using the CUE DUB button on the front panel (see page
recorded on the cue track regardless of the position of this switch.
3
This selects the output from channels 3 and 4 of the AUDIO OUT connectors.
MON: the signals selected by the MONITOR SELECT switches
LINE: the signals of audio channels 3 and 4
4MONITOR SELECT switches
These select the audio signals which can be monitored using the EARPHONE jack, HEADPHONES jack, and RFU OUT connector. When the
CUE: the audio from the cue track
DA: Use the channels selected by the switch to the right.
1/2: audio channels 1 and 2
3/4: audio channels 3 and 4
MIX: A mix of those of the four channels for which the corresponding switches below are in the ON position.
Chapter 2 Location and Function of Parts |