Page

Item

Setting

Description

 

 

GAMMA

LEVEL

–99~0~99

Sets the R, G, B, and master gamma

 

 

 

 

 

correction curve.

 

 

 

 

 

 

 

 

 

COARSE

0.40, 0.45,

Sets the master gamma correction

 

 

 

 

0.50

curve in terms of individual steps.

 

 

 

 

 

 

 

 

 

TABLE

STANDARD a)

Selects the gamma table.

 

 

 

 

1, 2, 3, 4, 5, 6

 

 

 

 

 

 

 

 

 

 

GAMMA

ON, OFF

Turns the gamma correction function

 

 

 

 

4

 

 

 

on or off.

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST

1, 2, OFF

Selects the test signal.

 

 

 

 

 

 

 

 

 

 

 

1: Outputs the analog test signal.

 

 

 

 

 

 

 

 

 

 

 

2: Outputs the digital test signal.

 

 

 

 

 

 

 

 

 

 

 

OFF: Does not output any test

 

 

 

 

 

signal.

 

 

 

 

 

 

 

 

a) STANDARD

1:INTIAL GAIN 3.5 (equivalent to ENG camcorder)

2:INTIAL GAIN 4.0 LOW (equivalent to EFP camera)

3:INTIAL GAIN 4.0 HIGH (equivalent to EFP camera))

4:INTIAL GAIN 4.0 (equivalent to SMPT-240M)

5:INTIAL GAIN 4.5 (equivalent to ITU-709)

6:INTIAL GAIN 5.0

Chapter 4 Adjustments and Settings for Recording 4-67