Page

Item

Setting

Description

 

 

 

 

 

 

KNEE

POINT

–99~0~99

Sets the R, G, B, and master knee point

 

 

 

R,G,B,M

 

level

 

 

 

 

 

 

 

SLOPE

–99~0~99

Sets the R, G, B, and master knee slope

 

 

 

R,G,B,M

 

level

 

 

 

 

 

 

 

WHT

–99~0~99

Sets the R, G, B, and master of the white

 

 

 

R,G,B,M

 

clipping level.

 

 

 

 

 

 

 

 

KNEE

–99~0~99

Sets the knee saturation level.

 

 

 

4

 

SAT

 

 

 

 

LEVEL

 

 

 

 

 

 

 

 

 

 

KNEE

ON,OFF

Turns the knee correction circuit on or off.

 

 

 

 

 

 

 

KEY

ON, OFF

Turns the knee saturation function on or

 

 

 

SAT

 

off.

 

 

 

 

 

 

 

WHT

ON, OFF

Turns the white clipping function on or off.

 

 

 

CLIP

 

 

 

 

 

 

 

 

 

 

TEST

1,

Selects the test signal.

 

 

 

 

 

 

 

 

 

2,

1: Outputs the analog test signal.

 

 

 

 

 

 

 

 

 

OFF

2: Outputs the digital test signal .

 

 

 

 

 

 

 

 

 

 

OFF: Does not output any test signal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chapter 4 Adjustments and Settings for Recording 4-69