Location and Function of Parts and Controls

Control Panel

w;

qg qh qj qk ql

 

 

 

 

 

 

LINE

LINE

RGB/

OPTION OPTION

 

 

 

 

 

 

A

B

COMPONENT

A

B

MENU

BRIGHT

CHROMA

PHASE

CONTRAST VOLUME

POWER

 

 

 

 

 

 

 

 

 

 

 

E X I T

 

 

 

 

 

 

RESET

 

 

 

SELECT

 

 

 

 

 

DEGAUSS BLUE

UNDER

16 : 9

EXT

 

– +

MIN MAX PUR GRN MIN MAX MIN MAX

 

ENTER

 

 

 

 

 

 

ONLY

SCAN

 

SYNC

 

 

 

 

 

 

qf qd qs qa q; 9 87

6

5

4

3 2

1

aPOWER ! switch

Press this switch to turn on the monitor. The lamp will light up. Press this switch again to turn off the monitor.

bVOLUME controlcCONTRAST controldPHASE control

Note

When you use a PAL or component signal, phase cannot be adjusted.eCHROMA controlfBRIGHT (brightness) controlgMENU/EXIT buttonPress this button to show or hide on-screen menus.hENTER/SELECT buttonPress this button to confirm an item selected on the menu.iM/+ (move the cursor up/adjust the value) buttonm/– (move the cursor down/adjust the value)buttonPress these buttons to move the cursor or adjust an item selected on the menu.

jEXT SYNC (external sync) button and lamp Press this button to operate the monitor synchronized with an external sync signal input through the EXT SYNC connector.

k16:9 button and lampPress this button to monitor a signal whose aspect ratio is 16:9.lUNDERSCAN button and lamp Press this button for underscanning.

The display size is reduced by approximately 5% so that the four corners of the picture are visible.

mBLUE ONLY/RESET button and lamp

As the BLUE ONLY button, press this button to eliminate the red and green component of input signals. Only the blue component of an input signal is displayed on the screen. This facilitates adjustments of chroma and phase, and observation of VCR noise. (Phase adjustment is effective only for NTSC signals.)

As the RESET button, you can reset the menu item setting to the previous one by pressing this button while the new item is being selected and adjusted.

nDEGAUSS button and lamp

Press this button only once. The screen will be demagnetized. Wait for 10 minutes or more before using this button again.

Note

The DEGAUSS button is disabled when the screen menu is being displayed.

To manually degauss the monitor, first, exit the screen menu by pressing the MENU/EXIT button.

oLINE A button and lampPress this button to monitor the signal input through the LINE A connectors.pLINE B button and lampPress this button to monitor the signal input through the LINE B connectors.

24 Location and Function of Parts and Controls