Names and Functions of Controls on Screen

1.4 OUTPUT Screen

You can set the parameters of the output block of the SRP-X700P from the OUTPUT screen.

1.4.1 OUTPUT OVERVIEW Screen

This screen corresponds to the output module of the audio mixer. This screen enables you to set the following.

The OUTPUT 1 through OUTPUT 8 correspond to the LINE OUTPUT 1 through LINE OUTPUT 8 of the main unit.

w; 9 ql
qh qg qj
wa ws

1

qk

wg wd wf

 

2

3

4

56

78

0

qs

qf

qa

 

qd

 

1OUTPUT index

Displays the index that is input on the BLOCK screen.

2OUTPUT level meter

Displays the output signal level by the VU response.

3REF LEVEL selection box

You can set the reference output level for each output channel. You can set it to –10, –5, 0 or +4 dBu for OUTPUTs 1 and 2. You can set it to –10, –5 or 0 dBu for OUTPUTs 3 to 8.

4Setup... button

By clicking the Setup button, the display jumps to the OUTPUT EQ screen where you can set the various equalization functions as shown below.

5EQ (EQualizer) button

Turns on and off the equalizer.

The EQ (EQualizer) button lights in green when the EQ button is pressed ON.

6HCF (High-cut Filter) indicator

The HCF indicator lights in green when the high-cut filter is pressed ON.

7DELAY button

Turns on and off the delay function.

The DELAY button lights in green when the delay is pressed ON.

8DELAY value setup box

You can set the delay time value from this setup box. Clicking the v or V button allows you to set the DELAY value in

2.9-ms steps in the range of 0ms to 150.8 ms. Alternatively, you can set DELAY in 1-m steps in the distance range of 0m

to 52 m, or in 3.33-ft steps in the range of 0 ft to 173.3 ft. You can also enter numerical values directly in the setup box. To switch the units, use the 9 DELAY UNITS setup box.

9DELAY UNITS setup box

The DELAY UNITS setup box allows you to select the unit of the delay as shown below. Clicking the DELAY UNITS setup box indicates the units. Select the desired unit.

In units of time: ms

In units of distance: meter, feet

0MUTING button

Mutes the output signals of the respective channels. The MUTING button lights in red when muted.

qa GAIN LIMIT and qs OVER GAIN indicator

The output level of the output channel is the sum of the SRP- X700P master volume on the GROUP FADER screen and the remote control via the remote terminal on the REMOTE screen.

You can set the upper limit of the output level by the

qa GAIN LIMIT to prevent excessive output level caused by using multiple volume controls. Each click of the [+] or [--]button increments or decrements the output level by 1 dB in the range of +10 dB to –10 dB. You can enter numerical values directly on the screen.

If the output level exceeds the GAIN LIMIT value, the actual output level is limited to the GAIN LIMIT value and the qs OVER GAIN indicator lights in red.

qd indicator

If there is no output sound when muted or when the OUTPUT fader is at the level position, the indicator lights in yellow.

16